RS232 and RS422 for Computer Systems

Data Line Surge Suppressors:

RS232/DB25 AND RS422/DB9

(Except the connection, specifications for both are the same)

Specifications - Operating:

Maximum Operating Voltage:

16 Volts

Typical Leakage Current:

<5 amps

Maximum Data Rate:

22K bps

Operation Temperature:

-40 to +85 C

DB25 Connection:

DB25 Male (Protected)

DB25 Female (Unprotected)

Pins Protected: 1, 9, 19 & 20

DB9 Connection:

DB9 Male (Protected)

DB9 Female (Unprotected)

Pins Protected: 4, 5, 8, and 9. Pin 1 = Shield/Ground

Specifications – Electronic:

Maximum Surge Current (8x20us):

5,000 Amps Total

Maximum Surge Voltage (1.2X50us):

6,000 Volts

Capacitance:

<120 pf

Clamping Voltage:

16 Volts

Clamping Response Time:

<5 nanoseconds

Current:

Non-Load Bearing

Three Stage Protection:

1st Stage: 5,000 Amps per line

2nd Stage: Filter Section

3rd Stage: 100,000 Volts Amp

Pass Voltage Tested to ANSI/IEEE:

B3 Impulse <30 Volts

Data Line
Protectors are available for Arc net, AS400, BNC Control Line,
Ethernet, LAN, RISC, RS232, Token Ring, 10Base T, 100 Base T or any low
voltage AC or DC signal circuits requiring protection. Terminations are available for almost any computer with stand off voltage from 5 volts to 200 volts. Our Data Line Protectors are non-load bearing. Call for pricing and availability

E-Clips Surge Suppressors have a Lifetime Product Warranty. Please see warranty statement for complete product warranty information.