DLT 3S 200V DSL for Computer or Telephone Systems

DSL Surge Suppressor

DLT 3S 200V DSL

The E-Clips DSL incorporates state of the art technology and provides multi stage hybrid protection for your communication lines. Tested to ANSI/IEEE B3 impulse standards and UL 497B. Unlike other communication line surge suppressors, E-Clips DSL goes far beyond industrial grade surge suppressors. It is self-restoring after each surge within ratings.

This unit is 200 Volts DC and should be used for modems connected to digital signal line or telephone line with ring voltage.   The DLT 3S/200 has RJ11 jack and plug and should be installed at the PC.

Specifications/Operating:

Maximum Operating Voltage:

5 V - 200 V (specify voltage)

Typical Leakage Current:

< 5u amps

Maximum Data Rate:

10Mhz

Operation Temperature:

-40 c to +85c

Connectors:

Terminal Block or RJ11

Lines Protected:

One Pair

Installation Configuration:

In-Line Series

Specifications/Electronic:

Maximum Surge Current (8 x 20us):

10,000 Amps Per Line

Maximum Surge Voltage (1.2 x 50us):

6,000 Volts

Capacitance:

<250 pf

Clamping Voltage:

Volts DC as designated

Clamping Response Time:

<5 Nanoseconds

Voltage:

Voltage Sensitive

Pass Voltage Test to ANSI/IEEE B3:

10% Above Normal

Power Dissipation (8 x 20us):

60,000,000 VA Protection Per Line

Dimension:

Depth: 1" Width: 2" Length: 1 ½"

Tabs: ½" each

E-Clips surge suppressors have a Lifetime Product Warranty. Please see warranty statement for complete product warranty information.