The
E-Clips D Dual 4W data line surge suppressor incorporates
state-of-the-art technology and provides multi-stage hybrid protection
for your equipment connected to your data lines. Tested
to ANSI/IEEE B3 Impulse Standards that exceed normal UL 497B testing
standards, this unit exceeds industrial grade surge protection without
loading your sensitive data lines and is self restoring after each
surge within ratings.
|
Specifications – Operating: |
|
|
|
|
|
Maximum Operating Voltage: |
5V DC, 12V DC, or 24V DC |
|
Typical Leakage Current: |
<5u Amps |
|
Maximum Data Rate: |
10Mhz |
|
Operation Temperature: |
-40 to +85 C |
|
Connectors: |
Dual Terminal Blocks |
|
Lines Protected: |
4 Lines (2 Pair) |
|
Dimensions: |
Length: 3†Width: 2†Height: 1 1/2 †|
|
|
|
|
Specifications – Electronic: |
|
|
|
|
|
Maximum Surge Current (8x20us): |
3,000 Amps |
|
Maximum Surge Voltage (1.2x50us): |
6,000 Volts |
|
Capacitance: |
<250 pf |
|
Clamping Voltage: |
6.8V DC, 15V DC, and 30V DC |
|
Clamping Response Time: |
<5 Nanoseconds |
|
Voltage Sensitive: |
Non-Load Bearing |
|
Pass Voltage Tested to ANSI/IEEE B3: |
<10V DC, 19V DC and 31V DC |
|
Power Dissipation (8x20us): |
1st. Stage: 3,000 Amps per line |
|
|
2nd Stage: Filter Section |
|
|
3rd Stage: 100,000 VA |
You must specify voltage required when ordering this unit
E-Clips surge suppressors have a Lifetime Product Warranty. Please see warranty statement for complete product warranty information.