CCTV

E-Clips

Surge Suppression products for Camera Systems:

CCTV BNC V or CCTV BNC C/V are hybrid coaxial units and should be installed at the camera and head end equipment. No external ground is necessary because these units dissipate within themselves. Passes both video and data.

CATV 24 VAC or CATV 12 VDC is a 24-volt AC parallel hardwire unit (or 12-volt VDC). The hardwire leads should go under screws on the camera for the 24-volt power source. A ground lug is provided and should only be used if you have a 3-wire application (phase, neutral, ground). If just using phase and neutral, you should not use the ground lug. This unit is not amperage sensitive.

1P Is a 110-Volt AC plug-in device for the camera.

3NF or 1206CS are 110-volt AC plug-in devices for the transformers, monitors, recorders, multi-plexers, switchers, amplifiers etc.

D Dual 4W 6.8 or D Dual 2W 6.8 are
in-line series screw terminal multi-stage hybrid devices for the four
wire (4W) or two wire (2W) data loop, pan/tilt (RS422) or twisted pair
video. These units pass both video and data. These should be installed at the camera, receiver driver, controller and or head end equipment. There is a ground lug provided. Only use if you have a common ground i.e. single ground for entire system to prevent ground loops.

D Dual 2W 60 is an in-line series screw terminal multi-stage hybrid device for power to cameras without heater blowers. This unit should be used for applications drawing 1 amp or less. A ground lug is provided and should only be used if you have a 3-wire application (phase, neutral, ground). If just using phase and neutral, you should not use the ground lug.

CCTV BNC V 32 – 19”
Rack mount 32 BNC (Female In/Female Out), 2 rack space surge suppressor
with In-Field Replaceable Modules for your multi-plexer or head end
equipment.

Grounding issues are very important. Should you have any questions or require assistance with the installation, please call 800-526-1556 for technical assistance.