Specifications – Operating: |
|
|
|
|
|
Maximum Operation Voltage: |
7.5 Volts DC |
|
Maximum Leakage Current: |
<5u amps |
|
Maximum Insertion Loss: |
<1 dB |
|
Weatherproof: |
Yes |
|
Connectors: |
BNC Female/Female |
|
|
BNC Female/BNC Male |
|
|
|
|
Specifications – Electronic: |
|
|
|
|
|
Maximum Surge Current (8 x 20us): |
500 Amps |
|
Maximum Surge Voltage (1.2 x 50us): |
6,000 Volts |
|
Capacitance: |
< 1.20pf |
|
Clamping Voltage: |
7.5 Volts |
|
Clamping Response Time: |
<5 Nanoseconds |
|
Current: |
Non-Load Bearing Voltage Sensitive |
|
Pass Voltage-ANSI/IEEE B3 Ring-wave: |
<15 Volts Peak |
|
Power Dissipation (8 x 20us): |
3,000,000 VA |
|
Typical Leakage Current: |
< 5u Amps |
|
Dimensions (Standard): Dimensions (Miniature): |
2†Length x 1.5†Width x 1†Height 1.5†Length x 1.250 Width x 0.800 Height |
E-Clips surge suppressors have a Lifetime Product Warranty. Please see warranty statement for complete product warranty information.