Fire Systems

E-Clips Surge Suppression Products for Fire Systems

E120H or 120H-PT: 120 Volt AC 3-Wire Single Phase surge suppressor and is designed to protect branch circuits, fire alarm or dedicated PLC equipment UL 1449 3rd Edition listed L-N, L-G, N-G with LED indicator.

T24MD: 30 Volts DC to be used on the initiating circuits, addressable loops, and NAC loops operating at 24 Volts DC to 34 Volts DC that are drawing less than 5 amps. These 2 pair devices have screw terminals; 4 in and 4 out.

T24MDP: 30 Volts DC to be used on the initiating circuits and addressable loops operating at 19 Volts DC to 33 Volts DC that are drawing less than 150 milliamps. These 2 pair devices have screw terminals; 4 in and 4 out.

T120MDP: 130 Volts RMS be used on equipment connected to your telecommunication lines with ring voltage digital dialers. These 2 pair devices have screw terminals; 4 in and 4 out.

RJ31120MDP: 130 Volts RMS to be used on equipment connected to your telecommunication lines with ring voltage with RJ31X. This device has Female RJ31X connectors; 1 in and 1 out.

FA-30: 30 Volts DC to be used on the initiating circuits and addressable loops operating at 24V DC that are drawing less than 1 amp.

FA-60: 60 Volts DC to be used on the initiating circuits and addressable loops operating above 24V DC (38V DC) that are drawing less than 1 amp.

DLT TOS 200: 200 Volts DC to be used on equipment connected to your telecommunication lines with ring voltage. i.e. (RJ31X)

Displaying products 1 - 10 of 10 results
DLTTOS200 - 200V DC ILDCP Series - Isolated Loop Circuit Protector for Communication Lines - Hybrid Inline Series
Part Number: DLTTOS200
Price: $75.00
DLTTOS200 - 200V DC ILDCP Series - Isolated Loop Circuit Protector for Communication Lines - Hybrid Inline Series
200V DC Multi stage hybrid protection for your communication lines. Tested to ANSI/IEEE B3 impulse standards and UL 497B. It is self-restoring after each surge within ratings. The ILDCP is available with RJ11 or terminal block termination.
DLTTOS30 - 30V DC ILDCP Series - Isolated Loop Circuit Protector for Communication Lines
Part Number: DLTTOS30
Price: $75.00
DLTTOS30 - 30V DC ILDCP Series - Isolated Loop Circuit Protector for Communication Lines
24V DC Multi stage hybrid protection for your communication lines. Tested to ANSI/IEEE B3 impulse standards and UL 497B. It is self-restoring after each surge within ratings.
FA15 - 12V 3-Stage Initiating/Data Circuit Protector 2 wire
Part Number: FA15
Price: $75.00
FA15 - 12V 3-Stage Initiating/Data Circuit Protector 2 wire
Hybrid 12 Volt DC Isolated Loop Circuit Surge Protector. Multi stage hybrid protection for your communication lines. Tested to ANSI/IEEE B3 impulse standards and UL 497B. It is self-restoring after each surge within ratings.
FA30 - 24V 3-Stage Initiating/Data Circuit Protector 2 wire
Part Number: FA30
Price: $75.00
FA30 - 24V 3-Stage Initiating/Data Circuit Protector 2 wire
Hybrid 24 Volt DC Isolated Loop Circuit Protector. Multi stage hybrid protection for your communication lines. Tested to ANSI/IEEE B3 impulse standards and UL 497B. It is self-restoring after each surge within ratings.
FA60 - 38V 3-Stage Initiating/Data Circuit Protector 2 wire
Part Number: FA60
Price: $75.00
FA60 - 38V 3-Stage Initiating/Data Circuit Protector 2 wire
Hybrid 38 Volt DC Isolated Loop Circuit Protector. Multi stage hybrid protection for your communication lines. Tested to ANSI/IEEE B3 impulse standards and UL 497B. It is self-restoring after each surge within ratings.
MRJ31120MDP - RJ31X Telecom Surge Protector
Part Number: MRJ31120MDP
Price: $59.98
MRJ31120MDP - RJ31X Telecom Surge Protector
ECLIPS RJ31X Telephone Line Protector for Alarm Panels. The EClips MRJ31120MDP incorporates state of the art technology and provides multi stage hybrid protection for your communication lines. Tested to UL standards and is UL listed.
MT120MDP - 120V DC DIN and Snap Rail Mount Surge Protector
Part Number: MT120MDP
Price: $79.98
MT120MDP - 120V DC DIN and Snap Rail Mount Surge Protector
ECLIPS Dual Screw Terminal Telephone Line Protector for Alarm Panels ECLIPS Model MT120MDP Multi stage hybrid protection for your communication lines. Tested to UL standards and is UL listed. It is self-restoring after each surge within ratings.
MT24MD - 24V DC DIN and Snap Rail Mount Surge Protector
Part Number: MT24MD
Price: $69.98
MT24MD - 24V DC DIN and Snap Rail Mount Surge Protector
EClips 24 Volt DC Loop Circuit Protector. Fire Alarm Protection ECLIPS Model MT24MD multi stage hybrid protection for your 24 Volt DC Equipment. Tested to UL497 Standards and is UL listed. It is self-restoring after each surge within ratings.
MT24MDP - 24V DC DIN and Snap Rail Mount Surge Protector
Part Number: MT24MDP
Price: $79.98
MT24MDP - 24V DC DIN and Snap Rail Mount Surge Protector
EClips 24 Volt DC Loop Circuit Protector - Fire Alarm Protection ECLIPS Model MT24MDP multi stage hybrid protection for your 24 Volt DC Equipment. Tested to UL497 Standards and is UL listed. It is self-restoring after each surge within ratings.